360° LED Phototherapy
0.00৳
Item Name : Infant Incubator for NICU
Brand : NINGBO DAVID
Model : YP-100
Origin : Chin
Item Name: 360° LED Phototherapy
Brand : David
Model : XHZ-200
Origin : China
Specification:
Operating Environment
Ambient temperature: +20 ℃~ +28℃
Humidity: 30%~75%
Ambient air velocity: <0.3m/s
Phototherapy light source: Blue LED
Service life of light source: ≥50000 hours
Brief Introduction
- Equipped with a 360-degree blue light irradiation system
for 360-degree all-dimensional phototherapy treatment
for neonates with hyperbilirubinemia;
- The air temperature regulation system for providing a
suitable temperature environment;
- Double alarm for both air temperature and skin temperature
to ensure the safety of patient;
- Patient timing function: Under normal operating conditions,
the timer is stopped when the bed is pulled out, and the timer
will be turned on when the bed is in the position;
- Bed position detection function: The bed body shall be pulled
out for more than 10min to provide sound-light alarm and
alarm information;
- Large observation window to observe baby’s status.
Standard configuration
Top cabin :Including top light cabin (LED light source),
Controller, Tray;
Bottom cabin : Including bottom light cabin (LED light source),
Power requirement: AC220V/50Hz, 300VA
a
Features:
- Air mode control;
- Set temperature and air temperature are displayed separately;
- Natural air flow humidity;
- Multiple failure alarm indication;
- RS-232 connector;
- Configured with fixed Neonate bilirubin phototherapy equipment with blue fluorescent lamp;
Item Name: 360° LED Phototherapy
Brand : David
Model : XHZ-200
Origin : China
Specification:
Operating Environment
Ambient temperature: +20 ℃~ +28℃
Humidity: 30%~75%
Ambient air velocity: <0.3m/s
Phototherapy light source: Blue LED
Service life of light source: ≥50000 hours
Brief Introduction
- Equipped with a 360-degree blue light irradiation system
for 360-degree all-dimensional phototherapy treatment
for neonates with hyperbilirubinemia;
- The air temperature regulation system for providing a
suitable temperature environment;
- Double alarm for both air temperature and skin temperature
to ensure the safety of patient;
- Patient timing function: Under normal operating conditions,
the timer is stopped when the bed is pulled out, and the timer
will be turned on when the bed is in the position;
- Bed position detection function: The bed body shall be pulled
out for more than 10min to provide sound-light alarm and
alarm information;
- Large observation window to observe baby’s status.
Standard configuration
Top cabin :Including top light cabin (LED light source),
Controller, Tray;
Bottom cabin : Including bottom light cabin (LED light source),
Power requirement: AC220V/50Hz, 300VA
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Related products
LED Neonatal Phototherapy
Infant Incubator
- Air mode control;
- Set temperature and air temperature are displayed separately;
- Natural air flow humidity;
- Multiple failure alarm indication;
- RS-232 connector;
- Configured with fixed Neonate bilirubin phototherapy equipment with blue fluorescent lamp;
Infant Radiant Warmer
- Pre-warm mode control, manual mode control and baby mode control by micro-computer;
- Control Mode : Pre-warm mode , manual mode and baby mode are controlled by micro –computer
- Baby Mode temperature control range : 5°C-65°C
- Accuracy of skin temperature sensor : ±0.2°C
- Temperature uniformity of mattress : ≤2°C
- Angle of heater head : 0°-90° a ny angle for two ways
- Inclination of the bassinet : three tilt position
- Apgar timer : audible and visible alarm when the
- Set temperature and baby temperature can be displayed separately;
- Horizon angle of heater head and inclination of the bassinet can be adjusted;
- The panels around bassinet can be turned outward;
- X-ray cassette under the bassinet; APGAR timer;
- Failure alarm indication; RS232
- Power Requirement : AC220V-230V/50Hz
Bubble CPAP
Automatic Yuwell Electric Suction Machine 7A-23D
Automatic Yuwell Electric Suction Machine 7A-23B
Surgical Diathermy Machine (250W)
| Model: NAZ-SD-01 Modes: Bipolar and monopolar. Applications: Suitable for general surgery, dermatology, gynecology, vascular surgery, heart/thoracic surgery, ORL/ENT, TUR orthopedics, oral surgery, urology, etc. Functions: Offers precise cutting and coagulation with adjustable power settings. Safety: Features include a foot switch for control and low leakage current. Technical Specs: Output Power: 10-250W (Cut), 10-180W (Blend), 10-150W (Coag), 10-80W (Bipolar). Frequency: 400kHz. Power Source: AC220V/50/60Hz. Weight: 5.8 kg. Accessories: Includes monopolar handle, patient plate & cable, bipolar forceps & cable, foot switch, and power cable. |